![]() |
![]() |
![]() |
![]() |
||||||
| |
|||||||||
The Cattron-Theimeg CS (Crane Specific) system provides industry with a high performance, low-cost digital Portable Radio Remote Control (PRRC) alternative. The CS system is a low-cost product that is easy to install and maintain. Designed to be ready for use right "off-the-shelf", the CS is perfect for overhead cranes and other types of machinery with reversing motors. It does not require an operating license and can be easily installed and ready for use at the job site in a relatively short period of time. The CS System offers the end user up to 65,000 different addresses; thus, the chance for duplicate operating addresses is minimal to none. In addition, the CS offers "Output Relay Interlocking." This feature insures that the directional relays are interlocked to allow only one closure at a time, e.g., Forward or Reverse. The CS System is comprised of two primary components: a receiver/decoder with relay interface and a choice of either Cattron-Theimeg's MK or PS controller / transmitters. (See Controller Page for complete information on the MK and PS controllers). The receiver/decoder and output relays are all laid out on a single circuit board housed within a compact, NEMA 12, IP65 steel enclosure. The single board design provides a simple way to change all of the electronics should a repair be required. The decoder makes extensive use of the microcomputer's self-diagnostic capabilities by using a two character display to show system status. The output relays are rated for heavy industrial loads, both resistive and inductive. A secondary contact on each directional relay is used by the decoder to sense and verify each of the radio transmitter commands. Should a fault condition be detected in the directional relays, the OPR and all motion outputs will be disabled. Automatic Safety Override (ASO) is a safety feature in most Cattron-Theimeg systems. Key Features:
Technical Specifications: Relay Contact Rating: 5A @30 VDC or 250 VAC, resistive Output Relay Interlocking: Directional relays are interlocked to allow only one closure at a time, e.g., Forward OR Reverse Output termination: European "Plug-in" style Number of outputs: 4, 8, 12, or 16 electromechanical (ON/OFF functions plus 1 output for OPR mainline) Enclosure Dimensions and Rating: 10" x 8" x 4" (254mm x 203mm x 102mm); NEMA 12, IP65 Control Voltage Range: 30 VDC or 120 - 250 VAC +/- 20%, fused @ 15Amps Power Requirements: 13.8 VDC nominal; 110 VAC supply standard Diagnostics: Power on self diagnostics and a 2 character display to report status; individual LEDs for each output relay Receiver frequency: synthesized, 128 channel (selected via rotary and SIP switch); 447 - 473 MHz band Address Codes: 65,000; factory selection, sequential to build Sensitivity: 0.7uV (20db quieting) Frequency Stability: +/- 0.0005% of reference frequency Available Models: CS4 2 motors, single speed + OPR CS8 3 motors, single speed + 2 aux. functions + OPR CS12 4 motors, single speed + 4 aux. functions + OPR CS12+2 3 motors, two speed + 3 aux. functions + OPR CS16-4 4 motors, two speed + 3 aux. functions + OPR CS6DP 2 motors, two speed + OPR CS12DP 4 motors, two speed + OPR CS16DP 4 motors, two speed + 4 aux. functions
+ OPR * specifications subject to change without notice ** CS Systems are NOT compatible with other Cattron-Theimeg systems. |
|||||||||
Copyright© 1997 CATTRON-THEIMEG. All Rights Reserved. US |
|||||||||